Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Clin Chem Lab Med ; 60(9): 1486-1491, 2022 08 26.
Article in English | MEDLINE | ID: covidwho-1910717

ABSTRACT

OBJECTIVES: Coronavirus disease (COVID-19) can present with various symptoms and can involve multiple organs. Women infected during pregnancy have a higher incidence of obstetrical complications and infants born to "positive" mothers may get the infection with different manifestations. Presepsin seems to be a promising sepsis biomarker in adults and neonates. The aim of this study was to assess if presepsin levels in neonatal cord blood could be influenced by maternal severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. METHODS: A total of 119 neonates born from women with a confirmed diagnosis of SARS-CoV-2 infection were enrolled and presepsin levels of cord blood samples were collected. All neonates were tested for SARS-CoV-2 infection at birth and after 48-72 h. RESULTS: The median presepsin value in umbilical cord blood samples collected after birth was 455 pg/mL. Presepsin levels were not influenced by maternal symptoms of COVID-19, weight for gestational age, or delivery mode, and did not significantly differ between infants with and without adverse neonatal outcomes. Infants hospitalized for more than 5 days had a significantly higher presepsin level at birth rather than those discharged up to 4 days of life. Three infants with positive nasopharyngeal swab at birth had higher Presepsin levels than two infants tested positive at 48 h. CONCLUSIONS: This is the first study reporting cord presepsin levels in term and preterm infants born to mothers with COVID-19, that appeared to be not influenced by maternal clinical presentation. However, further studies are needed to explain the mechanisms of P-SEP increase in neonates exposed to perinatal maternal SARS-CoV-2 infection or with an indeterminate/possible SARS-CoV-2 infection in the same neonates.


Subject(s)
COVID-19 , Adult , COVID-19/diagnosis , Female , Fetal Blood , Humans , Infant, Newborn , Infant, Premature , Infectious Disease Transmission, Vertical , Lipopolysaccharide Receptors , Peptide Fragments , Pregnancy , SARS-CoV-2
2.
Neonatology ; 119(1): 129-132, 2022.
Article in English | MEDLINE | ID: covidwho-1518192

ABSTRACT

The COVID-19 pandemic has upset habits in any workplace. In hospitals, several precautions have been taken to maintain health-care workers' safety and to avoid disease spread or the possible creation of new epidemic outbreaks. The use of medical devices makes the contamination and the nosocomial virus spread possible, causing infection in medical operators and hospitalized patients. In the neonatal intensive care unit, ultrasound has been an increasingly used tool because it is a non-invasive, repeatable method and it is side effect-free as the newborn is not exposed to radiation. It makes a fast diagnosis and then therapy possible such as in the lung diseases and other life-threatening conditions. The use of portable devices such as the wireless probe has many advantages in routine clinical practice, and during the COVID-19 pandemic, it has proved to be fundamental for the patient and the physician's safety because it reduced the risk of contamination. We report the use of the wireless ultrasound probe in 2 isolated neonates born to SARS-CoV-2-positive mothers.


Subject(s)
COVID-19 , Pregnancy Complications, Infectious , Female , Humans , Infant, Newborn , Infectious Disease Transmission, Vertical , Mothers , Pandemics , Pregnancy , Pregnancy Complications, Infectious/epidemiology , SARS-CoV-2
4.
J Med Virol ; 92(9): 1671-1675, 2020 Sep.
Article in English | MEDLINE | ID: covidwho-116658

ABSTRACT

A pandemic of coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been spreading throughout the world. Though molecular diagnostic tests are the gold standard for COVID-19, serological testing is emerging as a potential surveillance tool, in addition to its complementary role in COVID-19 diagnostics. Indubitably quantitative serological testing provides greater advantages than qualitative tests but today there is still little known about serological diagnostics and what the most appropriate role quantitative tests might play. Sixty-one COVID-19 patients and 64 patients from a control group were tested by iFlash1800 CLIA analyzer for anti-SARS CoV-2 antibodies IgM and IgG. All COVID-19 patients were hospitalized in San Giovanni di Dio Hospital (Florence, Italy) and had a positive oro/nasopharyngeal swab reverse-transcription polymerase chain reaction result. The highest sensitivity with a very good specificity performance was reached at a cutoff value of 10.0 AU/mL for IgM and of 7.1 for IgG antibodies, hence near to the manufacturer's cutoff values of 10 AU/mL for both isotypes. The receiver operating characteristic curves showed area under the curve values of 0.918 and 0.980 for anti-SARS CoV-2 antibodies IgM and IgG, respectively. iFlash1800 CLIA analyzer has shown highly accurate results for the anti-SARS-CoV-2 antibodies profile and can be considered an excellent tool for COVID-19 diagnostics.


Subject(s)
Antibodies, Viral/immunology , COVID-19/diagnosis , COVID-19/immunology , Immunoassay , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Luminescent Measurements , SARS-CoV-2/immunology , Aged , Aged, 80 and over , Antibodies, Viral/blood , Automation, Laboratory , COVID-19/virology , Female , Humans , Immunoassay/methods , Immunoassay/standards , Immunoglobulin G/blood , Immunoglobulin M/blood , Luminescent Measurements/methods , Luminescent Measurements/standards , Male , Middle Aged , ROC Curve , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL